Three technical aspects of three solutions for noise control of Bright Air Compressor

Time:2019-07-01     Views:726次

Bright air compressor is a general-purpose mechanical product with a large volume and a wide range. It is widely used in machinery, mining, chemical and construction sectors. The noise level it produces is high and the impact is large. It has become one of the important environmental noise pollution sources. From production to manufacturing, solving the noise problem of air compressors can improve the quality of products in one step. Solving the noise of air compressors can greatly help improve people’s livelihood and environmental pollution. The noise pollution of air compressors needs reasonable control. The country has already Increased investment in this area.

Noise pollution is also an important factor in environmental pollution. People living near factories or highways are more or less troubled by noise from mechanical equipment and automobiles. The use of noise pollution indicators as indicators for assessing factories and living environment has long been included in the national environmental protection standards. Then, equipment production suppliers should also have the responsibility and obligation to reduce noise pollution during the operation of machinery and equipment through technical means, and to better create a low-decibel working and living environment.

The control of air compressor noise mainly adopts three aspects: muffler, silencing tunnel and sound insulation technology

1. Install air compressor muffler

The main noise source is the intake and exhaust ports, and appropriate intake and exhaust mufflers should be selected. The frequency spectrum of air compressor intake noise presents low-frequency characteristics, and the intake muffler should use a resistant structure or an impedance composite structure based on individual and resistance. The exhaust air pressure of the air compressor is large and the air flow velocity is high. A small hole muffler should be used at the air compressor exhaust port.

2. Set up air compressor silencing tunnel

The underground or semi-underground tunnel of the anechoic tunnel, the wall of the tunnel is made of bricks with good sound absorption. Connect the intake pipe of the air compressor to the silencing tunnel, so that the air enters the air compressor through the silencing tunnel. The use of muffler tunnels can greatly reduce the intake noise of the air compressor, and the service life is longer than that of general mufflers.

3. Establish a sound insulation cover

After installing mufflers at the intake and exhaust ports of the air compressor or silencing tunnels, the airflow noise can be reduced to below 80db(a), but the mechanical noise and motor noise of the air compressor are still very high, so the air compressor Install a sound insulation cover on the unit of the machine.

4. Suspended space sound absorber

In the air compressor station, the tall and empty factory buildings have heavy reverberation. If the sound absorber is dispersed on the roof of the factory building, the noise of the factory building can be reduced by 3-10db(a), and the reverberation time can be reduced by 5-10s.